Narayani Electric Co. has been in the business as L&T ACB Supplier in Kolkata, West Bengal, Bihar, Odisha, Jharkhand, Chattishgarh Assam & all over India for over two decades. The company offers a wide range of C power ACB that are designed to protect industrial motors from damage and malfunction. Their solutions include motor overload protection, temperature protection, and vibration protection.

The L&T ACB supplier by Narayani Electric Co. are designed to protect the motor from excessive load, which can cause the Circuit Breakers to overheat and malfunction. The L&T ACB offered by the company protect the Air from high temperatures, which can lead to damage and malfunction. Finally, the vibration protection solutions offered by the company protect the Circuit Breakers from excessive vibration, which can cause the Breakers to malfunction.

Range of L&T ACB

L&T ACB Supplier
  • Complete range conforms to IS/IEC 60947-2 & IEC 60947-2
  • Current Rating from 400A to 6300A in 3 Frame sizes for application voltages upto 690V AC
  • Special ACB range available for Voltage Applications upto 800V AC and 1000V AC#
  • Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed/Draw-out version
  • Common Height & Depth across the range
  • High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
  • High mechanical and electrical operating life
  • Neutral pole is 100% rated, option of 50% & 200% rated neutral also available
  • Available in standard NRYB & RYBN/NBYR/BYRN configurations in 4 Pole ACBs with on-site change facility
  • In-built Electrical & Mechanical Anti-Pumping
  • Modular & snap-fit accessories
  • Ease of on-site conversion from Fixed to Draw-out version
  • Pollution Degree 4 suitability
  • Best in Class Overlap with Bus bars
  • Break Time of 25msec
  • RoHS Compliant

Matrix Protection & Control Units:

L&T ACB Supplier
L&T ACB Suppliers
  • Available in versions – 0/1G/1Gi/1.5G/1.5Gi, MTX3.5/3.5EC/3.5H & MTX4.5
  • Unique O-LED display for metering
  • Touch screen technology in UW-MTX4.5
  • Unique withdrawable Communication & Power metering modules
  • Dual protection curve settings & Password protection
  • Soft-rating plug for precise protection at lower load currents
  • Provision for on-load self-diagnosis of Releases & modules
  • Data communication on Modbus, Profibus & wireless Zigbee protocols
  • Power & Harmonics measurement
  • Temperature rise monitoring & protection
  • Easy to integrate with HMI & PLC
  • Add-on modules for advance protections
  • Protection Releases conform to EMI/EMC standard

Breaking Capacities Offered:

At 415V/440V AC (Please refer Catalogue for Breaking Capacities above 440V AC)

ACBs are offered with following standard features:

Draw-out Version 

Omega ACBs with UW-MTX release will have inbuilt-

Current Metering (MTX 1.5G/1.5Gi/3.5/3.5EC/3.5H/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Smart-racking shutter, Safety shutter assembly, Racking Handle, Door sealing frame, Pad-locking arrangement for ON/OFF button, Rating Error Preventer, Arc shield.

  • For ratings upto 1600A, one side vertical terminal adaptors (Bottom) for Frame 1, 2 &
  • For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom) for Frames 1, 2 &
  • For rating 4000A and above operation counter inbuilt for Frames 2 & 3
 

Fixed Version 

Omega ACBs with UW-MTX release will have inbuilt-

Current Metering (1.5G/1.5Gi/3.5/3.5EC/3.5H/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Door sealing frame & Pad-locking arrangement for ON/OFF push button.

  • For ratings upto 1600A, one side vertical terminal adaptors (Bottom) for Frames 1, 2 &
  • For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom) for Frames 1, 2 &
  • For ratings 4000A & above, operation counter inbuilt for Frames 2 & 3

Electrically operated ACB includes ECD, CR & SR as per selection of above mentioned control voltage options.

3 Pole ACBs upto 690V AC with UW-MTX1G (LSING - BCD Switches)

3-Pole-ACBs-
3-Pole-ACBs-1
3-Pole-ACBs-2
  Current Rating     Version 3 Pole Manual Draw-out ACB with UW-MTX1G
N (50kA @ 415 AC) S (65kA @ 415 AC) H (80kA @ 415 AC) V (100kA @ 415 AC)
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit
800A             MDO UW108NXD01800 UW108SXD01800 UW108HXD01800 UW308VXD01800
1000A UW110NXD01800 UW110SXD01800 UW110HXD01800 UW310VXD01800
1250A UW112NXD01800 UW112SXD01800 UW112HXD01800 UW312VXD01800
1600A UW116NXD01800 UW116SXD01800 UW116HXD01800 UW316VXD01800
2000A UW120NXD01800 UW120SXD01800 UW120HXD01800 UW320VXD01800
2500A UW225NXD01800 UW225SXD01800 UW225HXD01800 UW325VXD01800
3200A UW232NXD01800 UW232SXD01800 UW232HXD01800 UW332VXD01800
4000A UW240SXD01800 UW240HXD01800 UW340VXD01800
4000A UW340HXD01800 UW340VXD01800
5000A UW350HXD01800 UW350VXD01800
6300A UW363HXD01800 UW363VXD01800
 

Quick links

3 Pole Manual Fixed ACB with UW-MTX1G
800A             MF UW108NXF01800       UW108SXF01800         UW108HXF01800           UW308VXF01800  
1000A UW110NXF01800 UW110SXF01800 UW110HXF01800 UW310VXF01800  
1250A UW112NXF01800 UW112SXF01800 UW112HXF01800 UW312VXF01800  
1600A UW116NXF01800 UW116SXF01800 UW116HXF01800 UW316VXF01800  
2000A UW120NXF01800 UW120SXF01800 UW120HXF01800 UW320VXF01800  
2500A UW225NXF01800 UW225SXF01800 UW225HXF01800 UW325VXF01800  
3200A UW232NXF01800 UW232SXF01800 UW232HXF01800 UW332VXF01800  
4000A UW240SXF01800 UW240HXF01800 UW340VXF01800  
4000A UW340HXF01800 UW340VXF01800  
5000A UW350HXF01800 UW350VXF01800  
6300A UW363HXF01800 UW363VXF01800  
 
M.R.P. changes for product customization
MDO to EDO or MF to EF Conversion kit (ECD + CR + SR)
Buscoupler (without protection release)
UW-MTX1.0 (LSI – BCD Switches)
UW-MTX1Gi (LSING + Inbuilt ZSI – BCD Switches)
UW-MTX1.5G (LSING + Current Metering – BCD Switches)
UW-MTX1.5Gi (LSING + Current Metering + Inbuilt ZSI – BCD Switches)
UW-MTX3.5 (LSING + Current Metering) + can be upgraded for Power Metering & Communication
UW-MTX3.5EC (LSING + Power Metering + Communication)
UW-MTX3.5H (LSING + Power Metering + Harmonic Metering)
UW-MTX4.5 (LSING + Power Metering + Harmonic Metering + Communication with Touch Screen navigation + UW-PS Module)
UW-PS (Auxiliary power supply module for display in No-load or OFF condition)$
COM Module (MODBUS) for communication$
PM Module for power metering$

4 Pole ACBs upto 690V with UW-MTX1G (LSING - BCD Switches)

4 Pole ACBs
4 Pole ACBs supplier
4 Pole ACBs suppliers
  Current Rating     Version 4 Pole Manual Draw-out ACB with UW-MTX1G
N (50kA @ 415 AC) S (65kA @ 415 AC) H (80kA @ 415 AC) V (100kA @ 415 AC)
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No.  
800A             MDO UW108NFD01800   UW108SFD01800   UW108HFD01800   UW308VFD01800  
1000A UW110NFD01800 UW110SFD01800 UW110HFD01800 UW310VFD01800  
1250A UW112NFD01800 UW112SFD01800 UW112HFD01800 UW312VFD01800  
1600A UW116NFD01800 UW116SFD01800 UW116HFD01800 UW316VFD01800  
2000A UW120NFD01800 UW120SFD01800 UW120HFD01800 UW320VFD01800  
2500A UW225NFD01800 UW225SFD01800 UW225HFD01800 UW325VFD01800  
3200A UW232NFD01800 UW232SFD01800 UW232HFD01800 UW332VFD01800  
4000A UW240SFD01800 UW240HFD01800 UW340VFD01800  
4000A UW340HFD01800 UW340VFD01800  
5000A UW350HFD01800 UW350VFD01800  
6300A UW363HFD01800 UW363VFD01800  
 
4 Pole Manual Fixed ACB with UW-MTX1G
800A           MF UW108NFF01800   UW108SFF01800   UW108HFF01800   UW308VFF01800  
1000A UW110NFF01800 UW110SFF01800 UW110HFF01800 UW310VFF01800  
1250A UW112NFF01800 UW112SFF01800 UW112HFF01800 UW312VFF01800  
1600A UW116NFF01800 UW116SFF01800 UW116HFF01800 UW316VFF01800  
2000A UW120NFF01800 UW120SFF01800 UW120HFF01800 UW320VFF01800  
2500A UW225NFF01800 UW225SFF01800 UW225HFF01800 UW325VFF01800  
3200A UW232NFF01800 UW232SFF01800 UW232HFF01800 UW332VFF01800  
4000A UW240SFF01800 UW240HFF01800 UW340VFF01800  
4000A UW340HFF01800 UW340VFF01800  
5000A UW350HFF01800 UW350VFF01800  
6300A UW363HFF01800 UW363VFF01800  

Accessories of Air Circuit Breakers

Terminal Adaptor configuration upto 690V AC

Draw-out ACBs Terminal Adaptors

  Description   Cat. No.
Terminal Adaptor for Draw-out Omega ACBs  
Frame-1 400-2000A N/S/H (Vertical / Horizontal) CL60963OOOO
Frame-1 2500A S/H (Vertical)   CL60964OOOO
Frame-2 400-3200A N/S/H (Vertical / Horizontal)
Frame-2 4000A S/H (Vertical) CL60420OOOO
Frame-2 4000A S/H (Horizontal) CL60316OOOO
Frame-3 400-4000A H/V (Vertical) # CL60128OOOO
Frame-3 400-4000A H/V (Horizontal-Long) CL60073OOOO
Frame-3 5000A H/V (Horizontal-Long) CL60966OOOO
Frame-3 5000A H/V (Vertical)# CL60067OOOO
Frame-3 6300A H/V (Vertical) # CL60965OOOO

Fix ACBs Terminal Adaptors

  Description   Cat. No.
Terminal Adaptor for Fixed Omega ACBs
Frame-1 400-2000A N/S (Vertical / Horizontal) CL60967OOOO
Frame-1 400-2000A H (Vertical / Horizontal) CL60968OOOO
Frame-1 2500A S/H (Vertical) CL60976OOOO
Frame-2 400-2500A N/S (Vertical / Horizontal) CL60122OOOO
Frame-2 400-3200A H, 3200A N/S (Vertical / Horizontal) CL60977OOOO
Frame-2 4000A S/H (Vertical) CL60417OOOO
Frame-3 400-4000A H/V (Vertical)# CL60418OOOO
Frame-3 5000A H/V (Vertical)# CL60347OOOO
Frame-3 400-5000A H/V (Horizontal-Long) CL60373OOOO

800V AC ACBs with UW-MTX1G (LSING - BCD Switches)

4 Pole ACBs
4 Pole ACBs supplier
4 Pole ACBs suppliers
800V AC Manual Fix/Draw-out ACB with UW-MTX1G
    Current Rating     Frame   Breaking Capacity @ 800V AC 3P 4P
Fix Draw-out Fix Draw-out
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit   Cat. No.
800A     1     50kA UW108NXF0180ZM   UW108NXD0180ZM   UW108NFF0180ZM   UW108NFD0180ZM
1000A UW110NXF0180ZM UW110NXD0180ZM UW110NFF0180ZM UW110NFD0180ZM
1250A UW112NXF0180ZM UW112NXD0180ZM UW112NFF0180ZM UW112NFD0180ZM
1600A UW116NXF0180ZM UW116NXD0180ZM UW116NFF0180ZM UW116NFD0180ZM
2000A UW120NXF0180ZM UW120NXD0180ZM UW120NFF0180ZM UW120NFD0180ZM
2000A     2     50kA UW220NXF0180ZM   UW220NXD0180ZM   UW220NFF0180ZM   UW220NFD0180ZM
2500A UW225NXF0180ZM UW225NXD0180ZM UW225NFF0180ZM UW225NFD0180ZM
3200A UW232NXF0180ZM UW232NXD0180ZM UW232NFF0180ZM UW232NFD0180ZM
4000A UW240NXD0180ZM UW240NFD0180ZM
3200A   3   50kA UW332NXF0180ZM   UW332NXD0180ZM   UW332NFF0180ZM   UW332NFD0180ZM
4000A UW340NXF0180ZM UW340NXD0180ZM UW340NFF0180ZM UW340NFD0180ZM
5000A UW350NXF0180ZM UW350NXD0180ZM UW350NFF0180ZM UW350NFD0180ZM
3200A   3   65kA UW332SXF0180ZM   UW332SXD0180ZM   UW332SFF0180ZM   UW332SFD0180ZM
4000A UW340SXF0180ZM UW340SXD0180ZM UW340SFF0180ZM UW340SFD0180ZM
5000A UW350SXF0180ZM UW350SXD0180ZM UW350SFF0180ZM UW350SFD0180ZM
M.R.P. changes for product customization M.R.P. (`) Per Unit
Buscoupler (without protection release)         *
UW-MTX1.0 (LSI – BCD switch for selection)
UW-MTX1G (LSING – BCD switch for selection)
UW-MTX1.5G (LSING + display – BCD switch for selection)
UW-MTX3.5 (LSING + Display + Option for other features)
UW-TM – Temperature Rise Module ( for MTX3.5)
MDO to EDO or MF to EF Conversion kit (ECD + CR + SR)
COM Module (MODBUS) for communication
UW-PS (Auxiliary power supply module for display in No-load or OFF condition)
   

Terminal Adaptors for 800V ACBs

Current Rating   Frame Fix Draw-out
  Cat. No. M.R.P. (`) Per Unit Qty (3P/4P)   Cat. No. M.R.P. (`) Per Unit Qty (3P/4P)
630A       1 CL60967OOOO   (6/8) CL60963OOOO   (6/8)
800A CL60967OOOO (6/8) CL60963OOOO (6/8)
1000A CL60967OOOO (6/8) CL60963OOOO (6/8)
1250A CL60967OOOO (6/8) CL60963OOOO (6/8)
1600A CL60967OOOO (6/8) CL60963OOOO (6/8)
2000A CL60122OOOO (6/8) CL60964OOOO (6/8)
2000A     2 CL60977OOOO (6/8) CL60964OOOO (6/8)
2500A CL60318OOOO (6/8) CL60964OOOO (6/8)
3200A CL60417OOOO (6/8) CL60419OOOO (6/8)
4000A CL60420OOOO (6/8)
3200A   3 CL60418OOOO (12/16) CL60128OOOO (12/16)
4000A CL60418OOOO (12/16) CL60067OOOO (12/16)
5000A CL60347OOOO (12/16) CL60965OOOO (12/16)
Draw-out ACBs Terminal Adaptors

Draw-out ACBs Terminal Adaptors

Draw-out ACBs Terminal Adaptors

Fix ACBs Terminal Adaptors

Phase-Barriers for 800V AC Fix ACBs

Cat. No. Type Pole M.R.P. (`) Per Unit Qty. per ACB
CL91258OOOO Fix 3P * 2
CL91259OOOO Fix 4P 2

Accessories of Air Circuit Breakers

Operation Counter

Operation Counter

Door Interlock

Door Interlock

  Description   Cat. No.  
Other Accessories [8538]
Operation Counter CL90983OOOO#  
Door Interlock CL90978OOOO  
Electrical Position Indication (EPI) CL95826OOOO  
Microswitches for Indication [8536]
Microswitch for Common Fault Indication (CFI) CL90949OOOO  
Microswitch for Ready To Close Indication (RTC) CL90953OOOO^  
Microswitch for Shunt Release CL90951OOOO  
Microswitch for Undervoltage Release CL90947OOOO  
Microswitch for Spring Charging Indication ST42672OOOO  
 
Closing Release supplier

Closing Release

Shunt Release supplier

Shunt Release

UV Release suppliers

UV Release

  Description   Cat. No. M.R.P. (`) Per Unit
Electrical Charging Device (ECD) [8501]
24-30V DC CL90362OOOO     *
48/60V DC CL90363OOOO
110V AC / 110-125V DC CL90360OOOO
220V AC / 200V DC CL90364OOOO
240V AC / 250V DC CL90359OOOO
415V AC / 400V DC CL90361OOOO
Closing Release (CR) [8538]
24-30V DC CL908174OOO     *
48/60V DC CL908175OOO
110V AC / 110V DC CL90817AOOO
125/127V DC CL908171OOO
220 – 240V AC / 220 – 250V DC CL90817BOOO
415V AC CL90817DOOO
Shunt Release (SR) [8538]
24-30V DC CL90816O4OO       *
48/60V DC CL90816O5OO
110V AC / 110V DC CL90816OAOO
125/127V DC CL90816O1OO
220 – 240V AC / 220 – 250V DC CL90816OBOO
415V AC CL90816ODOO
Under Voltage Release (UVR) with time delay (0-1-3-5 sec) [8538]
24-30V DC CL908184OOO     *
48V DC CL908185OOO
110V AC / 110V DC CL90818AOOO
240V AC / 220V DC CL90818BOOO
415V AC CL90818DOOO
 
R-Lock supplier

R-Lock

C-Lock suppliers

C-Lock

  Description   Cat. No.
Mechanical Interlock using Key & Lock$  
R – Lock Type – 1 CL00659OOOO
R – Lock Type – 2 CL00660OOOO
R – Lock Type – 3 CL00661OOOO
R – Lock Type – 12 CL00662OOOO
R – Lock Type – 23 CL00663OOOO
Locking arrangement for OFF button with R – Lock (on breaker)   CL90815OOOO
Locking arrangement for ISO position with R – Lock (on Cradle)   CL90865OOOO
Locking arrangement for ANY position with R – Lock (on Cradle)   CL90927OOOO
C – Lock Type – S CL00664OOOO
C – Lock Type – T CL00665OOOO
C – Lock Type – ST CL00666OOOO
C – Lock Type – SS CL00667OOOO
C – Lock Type – TT CL00668OOOO
Locking arrangement for OFF button with C – Lock (on breaker)   CL90814OOOO
Locking arrangement for ISO position for C – Lock (on Cradle)   CL90982OOOO
Locking arrangement for ANY position with C – Lock (on Cradle)   CL90981OOOO

NCT

Description   Cat. No. M.R.P. (`) Per Unit
External Neutral CT for UW-MTX Releases [8504]
Frame-1, 2 & 3 400-800A CL00717OOOO     *
Frame-1, 2 & 3 1000-1600A CL00718OOOO
Frame-1 2000-2500A CL00719OOOO
Frame-2 & 3 2000-4000A CL00720OOOO
Frame-3 5000-6300A CL00721OOOO
 

Automatic Transfer Controllers (ATC)

AuXC-2000 Controller

AuXC-2000 Controller

Type Cat. No. M.R.P. (`) Per Unit Std. Pkg. (Nos.)
AuXC-2000 controller ATC2000OOOO 30100 1

Mechanical Interlock using Bowden Cable

  Description   Cat. No.  
Mechanical Interlock using Bowden Cable (5 meters length)  
Between 2 Incomers CL90663OOOO  
Between 3 Incomers CL90664OOOO  
Between 2 Incomers & 1 Standby CL90665OOOO  
Between 2 Incomers & 1 Buscoupler CL90666OOOO  
Mechanical Interlock using Bowden Cable (3 meters length)  
Between 2 Incomers CL90659OOOO  
Between 3 Incomers CL90660OOOO  
Between 2 Incomers & 1 Standby CL90661OOOO  
Between 2 Incomers & 1 Buscoupler CL90662OOOO  
Mechanical Interlock using Bowden Cable (2 meters length)
Between 2 Incomers CL90810OOOO  
Between 3 Incomers CL90811OOOO  
Between 2 Incomers & 1 Standby CL90812OOOO  
Between 2 Incomers & 1 Buscoupler CL90813OOOO  
 
MODBUS Module

MODBUS Module

Power Metering Module

Power Metering Module

  Description   Cat. No.
MATRIX Releases & Modules [8538]
UW-MTX1.0 CL91966OOOO
UW-MTX1G CL91971OOOO
UW-MTX1Gi CL90562OOOO
UW-MTX1.5G CL91965OOOO
UW-MTX1.5Gi CL90552OOOO
UW-MTX3.5 CL90645OOOO
UW-MTX3.5EC CL90644OOOO
UW-MTX3.5H CL90646OOOO
UW-MTX4.5 CL90647OOOO
Power supply module CL90722OOOO
Relay Module CL90716OOOO
MODBUS Module CL90709OOOO
Profibus Module CL90295OOOO
Matrix Smart Card Module CL90705OOOO
Power Metering Module (415V) CL90649OOOO
Power Metering Module (690V) CL90685OOOO
ZSI Module CL90718OOOO
TCS Module CL90719OOOO
EL Module CL90720OOOO
REF Module CL90721OOOO
Simulation Kit CL90724OOOO

C-POWER Air Circuit Breakers

C-POWER S1 Range of Air Circuit Breakers

C-POWER S1 Range of Air Circuit Breakers

  • Conforms to IS/IEC 60947-2 & IEC 60947-2
  • Current rating from 400A to 3200A
  • Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
  • High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
  • High mechanical and electrical operating life
  • 100% rated neutral pole
  • Common height and depth across the range
  • Protection through Thermal – Magnetic (DN1) & Microprocessor releases (SR18G, SR18G+D & SR18Gi+D)
  • Self diagnostic Microprocessor based Releases with on-load testing through TEST button
  • Inbuilt thermal memory
  • Protection Releases conform to EMI/EMC standards
  • Breaker Status and Control through MODBUS protocol (UN-CO module)
  • Conforms to IS/IEC 60947-2 & IEC 60947-2
  • Current rating from 800A to 6300A
  • Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
  • High short time fault withstanding capacity, Icu = Ics = Icw for 1 sec for total selectivity
  • High mechanical and electrical operating life
  • 100% rated neutral pole
  • Protection through Thermal – Magnetic (DN1) & Microprocessor releases (SR18G, SR18G+D, SR18Gi+D & SR71)
  • Self diagnostic Microprocessor based Releases with on-load testing through TEST button
  • Inbuilt thermal memory
  • Protection Releases conform to EMI/EMC standards
  • Data communication & Power Management
  • Breaker Status and Control through MODBUS protocol (UN-CO module)
C-POWER Range of Air Circuit Breakers

C-POWER Range of Air Circuit Breakers

C-POWER S1 Range of Air Circuit Breakers

C-POWER HE ACBs for Harsh Environment

  • Designed to operate at peak efficiency in Sulphur-rich environments
  • Range 1250A to 5000A, 415/690V ac
  • Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed and Draw-out versions
  • Protection through Microprocessor release
  • Operates reliably in 3C4 environmental conditions of SO2 and H2S

 

Please contact the nearest branch office for Details & product Selection

C-POWER S1 3 & 4 Pole Draw-out ACBs

    Rating   Breaking Capacity Icu=Ics=Icw (1 sec)     Version
630A 50kA MDO
EDO
800A 50kA MDO
EDO
1000A 50kA MDO
EDO
1250A 50kA MDO
EDO
  1600A   50kA MDO
EDO
  2000A   50kA MDO
EDO
  2500A   60kA MDO
EDO
Microprocessor Based SR18G
3 Pole 4 Pole
Cat. No. M.R.P. (`) Per Unit Cat. No. M.R.P. (`) Per Unit
SL96041 186980 SL96061 234640
SL96051 233480 SL96071 281140
SL96042 186980 SL96062 234640
SL96052 233480 SL96072 281140
SL96043 194470 SL96063 245750
SL96053 240970 SL96073 292250
SL96044 214530 SL96064 270720
SL96054 261030 SL96074 317220
SL96045 243990 SL96065 300070
SL96055 290490 SL96075 346570
SL96046 286590 SL96066 352020
SL96056 333090 SL96076 398520
SL96047 354290 SL96067 426940
SL96057 400790 SL96077 473440
Thermal-Magnetic DN1
3 Pole 4 Pole
Cat. No. M.R.P. (`) Per Unit Cat. No. M.R.P. (`) Per Unit
SL95331 181480 SL95351 229140
SL95341 227980 SL95361 275640
SL95332 181480 SL95352 229140
SL95342 227980 SL95362 275640
SL95333 188970 SL95353 240250
SL95343 235470 SL95363 286750
SL95334 209030 SL95354 265220
SL95344 255530 SL95364 311720
SL95335 238490 SL95355 294570
SL95345 284990 SL95365 341070
SL95336 281090 SL95356 346520
SL95346 327590 SL95366 393020
SL95337 348790 SL95357 421440
SL95347 395290 SL95367 467940
 

C-POWER S1 3 & 4 Pole Fixed ACBs

    Rating Breaking Capacity Icu=Ics=Icw (1 sec)     Version
  630A   50kA MF
EF
  800A   50kA MF
EF
  1000A   50kA MF
EF
1250A 50kA MF
EF
1600A 50kA MF
EF
Microprocessor Based SR18G
3 Pole 4 Pole
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit
SL95561 116600 SL95581 148550
SL95571 163100 SL95591 195050
SL95562 116600 SL95582 148550
SL95572 163100 SL95592 195050
SL95563 127340 SL95583 160610
SL95573 173840 SL95593 207110
SL95564 146620 SL95584 183290
SL95574 193120 SL95594 229790
SL95565 162650 SL95585 209080
SL95575 209150 SL95595 255580
Thermal-Magnetic DN1
3 Pole 4 Pole
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit
SL95481 111100 SL95501 143050
SL95491 157600 SL95511 189550
SL95482 111100 SL95502 143050
SL95492 157600 SL95512 189550
SL95483 121840 SL95503 155110
SL95493 168340 SL95513 201610
SL95484 141120 SL95504 177790
SL95494 187620 SL95514 224290
SL95485 157150 SL95505 203580
SL95495 203650 SL95515 250080
M.R.P. changes for product customization w.r.t. SR18G ACB M.R.P.   M.R.P. (`) Per Unit
Bus – Coupler (w/o protection) Reduce 14200
Microprocessor based SR18G+D (LSING + Current Metering) Add 13000
Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 14500

C-POWER S1 Draw-Out ACBs will have inbuilt – 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating error preventor.

C-POWER S1 Fixed ACBs will have inbuilt – 2NO+2NC Aux contact for MF & 6NO+6NC Aux contact for EF breakers, Door sealing frame & Push-button cover. Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.

CN-CS…E Range 3 Pole Manual Fixed

    Rating   Breaking Capacity Icu=Ics=Icw (1 sec)     Version
400A 50kA 3P MF
630A 50kA 3P MF
800A 50kA 3P MF
1000A 50kA 3P MF
1250A 50kA 3P MF
1600A 50kA 3P MF
2000A 50kA 3P MF
Thermal-Magnetic Release Type DN1
  Cat. No. M.R.P. (`) Per Unit
SL95721OOOO 76570
SL95722OOOO 77250
SL95723OOOO 81750
SL95724OOOO 83850
SL95725OOOO 109840
SL95726OOOO 115650
SL93297OOOO 132710

C-POWER 3 & 4 Pole Draw-out ACBs

C-POWER 3 & 4 Pole Draw-out ACBs
C-POWER 3 & 4 Pole Draw-out ACB
    Rating Breaking Capacity Icu=Ics=Icw (1 sec)     Version     Type
800A 65kA MDO H
EDO H
1000A 65kA MDO H
EDO H
1250A 65kA MDO H
EDO H
  1600A   65kA MDO H
EDO H
  2000A   75kA MDO H
EDO H
  2500A   75kA MDO H
EDO H
  3200A   75kA MDO H2
EDO H2
4000A 75kA MDO H2
EDO H2
5000A 95kA MDO/EDO C
6300A 95kA MDO/EDO C
Microprocessor Based SR18G
3 Pole 4 Pole
Cat. No. M.R.P. (`) Per Unit Cat. No. M.R.P. (`) Per Unit
SL95311 306020 # 396500
SL95321 352520 # 443000
SL95312 311570 # 421400
SL95322 358070 # 467900
SL95313 340700 # 451870
SL95323 387200 # 498370
SL95314 383410 # 497480
SL95324 429910 # 543980
SL95315 431890 # 527710
SL95325 478390 # 574210
SL95316 440960 # 532030
SL95326 487460 # 578530
SL94822 447610 SL94826 549380
SL94824 494110 SL94828 595880
SL94823 518210 SL94827 672170
SL94825 564710 SL94829 718670
# * # *
# * # *
 
Thermal-Magnetic DN1
3 Pole 4 Pole
Cat. No. M.R.P. (`) Per Unit Cat. No. M.R.P. (`) Per Unit
# 300520 # 391000
# 347020 # 437500
# 306070 # 415900
# 352570 # 462400
# 335200 # 446370
# 381700 # 492870
# 377910 # 491980
# 424410 # 538480
# 426390 # 522210
# 472890 # 568710
# 435460 # 526530
# 481960 # 573030
SL94814 442110 SL94818 543880
SL94816 488610 SL94820 590380
SL94815 512710 SL94819 666670
SL94817 559210 SL94821 713170
# * # *
# * # *

C-POWER 3 & 4 Pole Manual Fixed ACBs

    Rating Breaking Capacity Icu=Ics=Icw (1 sec)     Version     Type
800A 50kA       MF       C
1000A 50kA
1250A 50kA
1600A 50kA
2000A 55kA
2500A 60kA
 
Microprocessor Based SR18G
3 Pole 4 Pole
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit
  *
SL97635 214450 # 278170
SL97636 236300 # 318560
Thermal-Magnetic DN1
3 Pole 4 Pole
  Cat. No. M.R.P. (`) Per Unit   Cat. No. M.R.P. (`) Per Unit
  *
SL93005 208950 # 272670
SL93006 230800 # 313060
 
M.R.P. changes for product customization w.r.t. SR18G M.R.P.   M.R.P. (`) Per Unit
Bus-Coupler (w/o protection) Reduce 14200
Microprocessor based SR18G+D (LSING + Current Metering) Add 13000
Microprocessor based SR18Gi+D (LSING + Current metering + ZSI) Add 14500
Microprocessor based SR71 (LSING + Current metering + Advance protection + PS Module) Add   *
Communication Module (MODBUS) for SR71 release (SR71 – COM)$ SL94698OOOO
Power Metering Module for SR71 release (SR71 – PM)$ SL94699OOOO
 

C-POWER Draw-Out ACBs will have inbuilt – 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating Error preventor. Option of horizontal & vertical termination upto 4000A also available. Operation counter for 4000A & above.

EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.

C-POWER Fixed ACBs will have inbuilt – 6NO+6NC Aux contact, Door sealing frame & Push-button cover. Operation counter for 4000A & above.

Accessories of C-POWER Air Circuit Breakers

Accessories (Common for C-POWER Family)

C-POWER Draw-Out ACBs will have inbuilt – 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating Error preventor. Option of horizontal & vertical termination upto 4000A also available. Operation counter for 4000A & above.

EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.

C-POWER Fixed ACBs will have inbuilt – 6NO+6NC Aux contact, Door sealing frame & Push-button cover. Operation counter for 4000A & above.

AN1 Module

AN1 Module

LTPB supplier

LTPB

LIP suppliers

LIP

  Description   Cat. No. M.R.P. (`) Per Unit
Lockable Trip Push Button (LTPB) [8301]
Type AA SL93148OOOA 4360
Type BB SL93148OOOB 4360
Type CC SL93148OOOC 4360
Type DD SL93148OOOD 4360
Lockable Trip Push Button kit (3 I/C & 2 B/C) SL91936OOOO 21780
Locking of ACB in Isolated position (LIP) [8301]
Type A SL93146OOOA 4360
Type B SL93146OOOB 4360
Type C SL93146OOOC 4360
Type D SL93146OOOD 4360
Locking of ACB in Any position (LAP) [8301]
Type A SL93147OOOA 4660
Type B SL93147OOOB 4660
Type C SL93147OOOC 4660
Type D SL93147OOOD 4660
Racking Interlock [8301]
Type AA SL93149OOOA 6010
Type BB SL93149OOOB 6010
Type CC SL93149OOOC 6010
Type DD SL93149OOOD 6010
Padlock [8301]
Racking Padlock Assembly CL90025OOOO 2040
Other Accessories [8538]
Door Interlock SL93150OOOO 3200
Mechanical Operation Counter* XM80837OOOO 3160
Mounting Kit for Front Mounted Counter SL95882OOOO 1120
Spring Charge Indication Microswitch SL96000OOOO 2540
Shunt Release

Shunt Release

UV Release

UV Release

  Description   Cat. No. M.R.P. (`) Per Unit
Shunt Release (SR) [8538]
Type EA : 24/48V DC SL92718O4OO 3410
Type EA : 110V DC SL92718O1OO 3410
Type EA : 220V DC SL92718O2OO 3410
Type EA1 : 110V AC SL92718OAOO 3410
Type EA1 : 240V AC SL92718OBOO 3410
Type EA1 : 415V AC SL92718ODOO 3410
Under Voltage Release (UVR) [8538]
Type MV : 24V DC ST36877OOOO 4920
Type MV : 240V AC SL92720BOOO 4920
Type MV : 415V AC SL92720DOOO 4920
Earth Fault Release ( for DN1) [8538]
Type EF1 (10%, 20% In ) SL91340OOOO 4350
Type EF2 (30%, 40%, 50% In) SL91341OOOO 4350
Remote Fault Indication [8538]
AN1 Remote Annunciation Module for SR18G/SR18G+D/SR18Gi+D : 240V AC   SL94654OOOO   10560
Microswitches for Indication [8536]
Microswitch for Voltmetric Releases (2) each SL92703OOOO 2700
Microswitch for Common Indication of O/L & S/C (3) each   SL92704OOOO   2700
Microswitch for Separate Indication of O/L & S/C (3) each (for DN1 release)   SL92705OOOO   4510
Service Position Microswitch – Right (2) SL93142OOOO 1830
Service Position Microswitch – Left (2) SL93143OOOO 1830
Test or Isolated Position Microswitch – Right (2) SL93144OOOO 1830
Test or Isolated Position Microswitch – Left (2) SL93145OOOO 1830
 
Draw-out ACBs Terminal Adaptors

Vertical Terminal Adaptor

  Description & Rating   Cat. No. M.R.P. (`) Per Unit Std. Pkg. (Nos.)
Vertical Terminal Adaptors for Draw out C-POWER ACB [8538]
400-1250 S1/800-1000 C SL93281OOOO 5440 1
1600-2000 S1/1250-1600 C/800-1600 H SL93282OOOO 6600 1
2000 C SL93284OOOO 9740 1
2000 H/2500 C/H SL93285OOOO 10180 1
2500 S1 SL93289OOOO 10180 1
3200 S1 SL93286OOOO 12530 1
3200H2/H1, 4000H2/H SL93288OOOO 30380 1
UN-CO module

UN-CO module

Features

  • Remote Status & Control of ACB
  • Communicates on MODBUS Protocol
  • Inbuilt RS485 Port

Spares of C-POWER Air Circuit Breakers

Protection Releases

SR71 supplier

SR71

SR18G+D/SR18Gi+D

SR18G+D/SR18Gi+D

SR18G

SR18G

DN1 supplier

DN1

Universal Test Kit

Universal Test Kit

Description   Cat. No. M.R.P. (`) Per Unit
Protection Releases [8538]
Microprocessor based type SR71 On Request
Microprocessor based type SR18Gi+D SL94813OOOO 55450
Microprocessor based type SR18G+D SL94812OOOO 53950
Microprocessor based type SR18G SL96030OOOO 40950
Thermal-Magnetic Release type DN1 SL93152OOOO 35450
Universal Test Kit CL90462OOOO 100320

Universal Test Kit

Compatible with following L&T Protection Releases:

  • SR protection releases of C-Power ACB family
  • UNRS protection releases of U-Power ACB family
  • MTX and RC releases of D-Sine MCCB family

 

Upgrade to high end communicable Release SR71

Retrofit kit solutions are available

For further details please contact the nearest branch office

 

CT

CT

  Description   Cat. No. M.R.P. (`) Per Unit Std. Pkg. (Nos.)
CTs for SR18G / SR18G+D / SR18Gi+D [8504]
400 S1 Fix & Draw-out SL01523OOOO 6430 1
630 S1 Fix & Draw-out ST37495OOOO 6430 1
800 C/H/S1 Fix & Draw-out SL01857OOOO 6430 1
1000 C/H/S1 Fix & Draw-out SL01858OOOO 6430 1
1250 C/H/S1 Fix & Draw-out SL90571OOOO 7780 1
1600 C/H/S1 Fix & Draw-out SL90572OOOO 7780 1
2000 C/H Fix & Draw-out SL90565OOOO 8630 1
2000 S1 Draw-out SL93210OOOO 8630 1
2500 C/H Fix & Draw-out   SL90566OOOO   8630   1
2500 S1 Draw-out
3200 H2/H1 Draw-out SL01740OOOO 9920 1
4000 H2/H Draw-out SL01739OOOO 11900 1