51, Ezra street ground floor Kolkata – 700001

Timing Devices, Supply Monitors & ELR

Timing Devices, Supply Monitors & ELR

Home // Timing Devices, Supply Monitors & ELR

Timing Devices, Supply Monitors & ELR Supplier

Timers

Micon 175
                         
Type Time Voltage Contact Arrangement Cat. No. M.R.P. (`) Per Unit
  ON Delay   0.3 sec – 30 hrs 240 VAC/24 VAC/DC   1 C/O 12ODT4 750
110 VAC/24 VAC/DC 11ODT4 1170
12 VDC 15ODT4 955
ON Delay & Interval   0.1 sec – 100 hrs   240 VAC/24 VAC/DC   1 C/O 12WDTC 930
Star Delta Timer 3 sec – 120 sec 240 VAC 1 NO (Star)+1 NO (Delta) 12SDT0 850
3 sec – 30 sec 240 – 415 VAC 1 C/O (Star)+1 C/O (Delta) 14SDT1S 1235
Signal OFF Delay 0.3 sec – 30 hrs 240 VAC/24 VAC/DC   1 C/O 12RDT4 880
0.3 sec – 30 hrs 12 VDC 15DDT4 955
Multifunction Timer   0.1 sec – 100 hrs   12 – 240 VAC/DC 1 C/O 1CMDT0 1495
2 C/O 1CMDTF 1590
Asymmetrical ON/OFF & OFF/ON   0.1 sec – 100 hrs   12 – 240 VAC/DC   1 C/O   1CJDT0   1495
  One Shot   0.3 sec – 30 hrs 110 VAC/24 VAC/DC   1 C/O 11BDT4 1110
240 VAC/24 VAC/DC 12BDT4 1110
12 VDC 15BDT4 1170
Forward Pause Reverse Timer ON time : 6 sec -60 min Pause time : 0.1 sec-200 sec   12 – 240 VAC / DC   2 C/O   1CZDTF   1590

Pause time for Micon 175 star delta timer is 60 msec

1CMDT0 contains ON Delay, Impulse, Signal ON delay, Cyclic ON/OFF, Cyclic OFF/ON, Signal OFF Delay, Signal OFF/ON, Accumulative Delay ON signal, Impulse ON/OFF, Leading edge impulse, Trailing edge impulse, Leading edge Bistable

 

Micon 225

Type Timing Range Voltage Contact Arrangement Cat. No. M.R.P. (`) Per Unit
ON Delay 0.1 sec – 10 hrs 24 – 240 VAC/DC 2 C/O 2AODT5 1360
Star Delta Timer 3 sec – 120 sec 24 – 240 VAC/DC 1 NO (Star)+1 NO (Delta) 2ASDT0 1430
240 – 415 VAC 2BSDT0 1680
Multifunction Timer 0.1s to 120 days 24 – 240 VAC/DC 2 C/O (1 Inst+1 Delayed) 2A8DT6 1525
Multifunction Multirange 0.1 sec – 10 hrs 24 – 240 VAC/DC 2 C/O 2A5DT5 1510
240 – 415 VAC 2B5DT5 1820
Signal Base Multi function – Multirange 0.1 sec – 10 hrs 24 – 240 VAC/DC 1 C/O 2ANDT0 1605
Multifunction Timer 6 Functions 0.1 sec – 10 hrs 24 – 240 VAC/DC 2 C/O (1 Inst+1 Delayed for 6th Mode) 2A6DT6 1620
240 – 415 VAC 2B6DT6 1655
True OFF Delay 0.6 sec – 600 sec 24 – 240 VAC/DC 2 C/O 23GDT0 2375
Asymmetrical ON/OFF 0.1 sec – 10 hrs 24 – 240 VAC/DC 2 C/O 2AADT5 1710

Pause time for Micon 225 star delta timer is 60 msec, 90 msec, 120 msec, 150 msec

Major timing functions

2A5DT5, 2B5DT5, 2A6DT6* and 2B6DT6* contains ON Delay, Interval, Cyclic ON/OFF, Cyclic OFF/ON, One Shot, ON Delay, On Delay (1 Inst + 1 Delayed)* 2ANDT0 contains ON Delay, Interval, Signal ON Delay, Accumulative ON Delay, Signal OFF Delay, Signal OFF/ON Delay, Leading edge impulse

2A8DT6 contains ON Delay, Impulse, Signal ON delay, Signal OFF delay, Step mode, One shot, Interval, Cyclic ON/OFF, Cyclic OFF/ON, Signal OFF Delay,

Digital Timer DIGICON
Functions Time Voltage Contact Arrangement Cat. No. M.R.P. (`) Per Unit
  8 Functions   0.1 sec – 999 hrs 24 – 240 VAC/DC 1 C/O V0DDTS 1615
24 – 240 VAC/DC 2 NO V0DDTD 1615
  18 Functions   0.1 sec – 999 hrs 24 – 240 VAC/DC 1 C/O V0DDTS1 1830
24 – 240 VAC/DC 2 NO V0DDTD1 1830

V0DDTS and V0DDTD contains On Delay, Signal OFF Delay, Cyclic ON/OFF, Signal OFF/ON, Cyclic OFF/ON, Interval, Signal ON/OFF, One Shot output V0DDTS1 and V0DDTD1 contains ON Delay, Cyclic OFF/ON, Cyclic ON/OFF, Impulse on energizing, Accumulative Delay ON Signal, Accumulative Delay on Inverted signal, Accumulative Impulse ON signal, Signal ON Delay, Inverted Signal On delay, Signal OFF Delay, Impulse ON/OFF, Signal OFF/ON, Leading edge impulse, Trailing edge impulse, Delayed impulse, Negative edge impulse.

Quick links

Motor Restart Timer
Type Timer Voltage Contact Arrangement Cat. No. M.R.P. (`) Per Unit
Motor Restart Timer Memory time Tm: 0.2 to 6 sec 110 VAC 1 C/O 23LDT0 1785
Delay time Td: 0.2 to 60 sec 240 VAC 22LDT0 1785

Time Switches

FM1 / Quartz   150 Hrs Battery Backup Product Description Cat. No. M.R.P. (`) Per Unit
    FM1 / Quartz Daily 240 VAC Base/DIN Mounting J648B1 2450
110 VAC Base/DIN Mounting J638B1 3330
240 VAC Flush Mounting J648F1 3095
110 VAC Flush Mounting J638F1 3230
    FM1 / Quartz Weekly 240 VAC Base/DIN Mounting J848B1 3330
110 VAC Base/DIN Mounting J838B1 3330
240 VAC Flush Mounting J848F1 3225
110 VAC Flush Mounting J838F1 3225
Digital Time Switch Crono Pro     Crono / Pulse Product Description Cat. No. M.R.P. (`) Per Unit
  Time Switch (Crono) 110 – 240 VAC 1 C/O Base/DIN 25 ON/OFF Each 67DDT0 2245
24 VDC 1 C/O Base/DIN 25 ON/OFF Each 6GHDT0 2590
12 VDC 1 C/O Base/DIN 25 ON/OFF Each 69HDT0 2730
Time Switch (Crono Pro) 110 – 240 VAC 2 C/O Base/DIN 50 ON/OFF Each WT2DCDS 3195
  Time Switch (Pulse) * 110 – 240 VAC 1 C/O Base/DIN 16 Pulse 67DDT9 2425
24V DC 1 C/O Base /Din 16 Pulse 6GHDT9 2745
12V DC 1 C/O Base /Din 16 Pulse 69HDT9 2885
* For bell and siren application
Astro Astro Pro       Astro Mini Product Description Cat. No. M.R.P. (`) Per Unit
Astro Mini 110 – 240 VAC 1 Phase – 2W 1 C/O , Base/Din T2DDT7 4200
Astro Pro 110 – 240 VAC 1 Phase – 2W 2 C/O , Base/Din 50 ON/OFF Each AS2DCDS 5710
Astro 110 – 240 VAC 3 Phase – 4W 3 Channel 3 N/O , Base/Din T3DDT0 10300

Supply Monitoring Devices

SPP includes single phasing, phase sequence and phase unbalance monitoring with auto reset

Voltage Monitoring Relay Series





SM 301







SM 500







SM 500 with Neutral Loss Protection







SM 501 Digital VMR Series







SM 800 SM 600 (MMR)
Type Supply Monitoring Type Time delay Asymmetry Voltage & Contact Arrangement Cat. No. M.R.P. (`) Per Unit
SM301 (3Ph, 3W) Single Phasing Preventor (SPP*) Fail Safe Type ON Delay 2 sec and OFF Delay 7 sec 65 VAC Asymmetry 415 VAC, 1 C/O MA51BC 985
415 VAC, 2 C/O MC21B5 1440
40 VAC Asymmetry 415 VAC, 1 C/O MA51BK 995
SM301 (3Ph, 3W) Phase loss monitoring Non Fail Safe Type OFF Delay 500 msec and Recover Delay 2 Sec 30% Fixed 415 VAC, 1 C/O MA59B5 1130
SM500 (3 Ph / 1 Ph, 4W) Selectable Under Voltage + Selectable Over Voltage Selectable ON Delay (0 to 15 min) 240 VAC, 1 C/O MD71B9 1480
Selectable ON Delay (0 to 15 sec) MD71BH 1480
Selectable OFF Delay (0 to 15 sec) MD71BF 1735
Single Phasing Preventor + Selectable Under Voltage + Selectable Over Voltage Selectable ON Delay (0 to 15 min) & OFF Delay 5 sec Phase Asymmetry 10% fixed 240 VAC, 2 C/O MG73B9 1815
Selectable ON Delay (0 to 15 sec) & OFF Delay 5 sec Phase Asymmetry 10% fixed MG73BH 1815
Selectable OFF Delay (0 to 15 sec) & ON Delay 5 sec Phase Asymmetry 10% fixed MG73BF 1815
SPP + UV/OV, with fixed UV (173 V) & OV (288 V) Selectable ON (10 Sec) and OFF Delay (5 Sec) Phase Asymmetry 20% fixed MG73BR 1815
SPP + Selectable UV + Selectable OV with Neutral Loss Protection ON Delay 5 sec and OFF Delay 5 sec, 500ms-1s for Neutral fail 94 VAC Asymmetry 415 VAC, 3 Ph 4W, 2 C/O MAC04 D0100 1815
SM501 (3 Ph, 3W) SPP + Under Voltage (80% of ) Selectable ON Delay and OFF Delay 15 sec Selectable Asymmetry (5% to 17%) 415 VAC, 2 C/O MB53BM 1850
Single Phasing Preventor + Selectable Under Voltage + Selectable Over Voltage Selectable ON Delay 15 sec & OFF Delay 5 sec Phase Asymmetry 10% MG53BH 1850
Selectable OFF Delay 15 sec & ON Delay 5 sec Phase Asymmetry 10% MG53BF 1850
ON Delay 5 sec and OFF Delay 5 sec 65 VAC Asymmetry MG53BI 1740
ON Delay 3 min and OFF Delay 5 sec UV Phase Asymmetry 10% MG53BO 1740
85% of OV 110% of
SM 800 (3PH/ 3W, 4W) Single Phasing Preventor+ Selectable Under Voltage + Selectable Over Voltage + Neutral Loss ( Applicable for 3P4W). Power ON Delay (0 to 999 sec) , OFF Delay (0.1 to 999 sec) & ON delay (0.5 to 999 sec) Voltage: 5 to 99 VAC (Default 60V) , Percentage : 2 to 50% (Default 10%) 145-500 VAC ( Line Voltage), 1C/O DMS110 1820
145-500 VAC ( Line Voltage), 2C/O DMS120 1920
85-300 VAC/DC (Auxiliary Supply) (P-N), 2 C/O DMA220 2120
SM 600 (3P, 3W) Phase loss+ Phase Sequence +Phase Asysmetery + UV + OV+3 phase interruption Power ON delay ( 5s Fixed),ON delay (1-30 sec or Fixed), OFF delay (0.1 – 30 sec or Fixed) Voltage +_ 1% of set value 500V -1000V AC 2 C/O SMB110 8550
Voltage Monitoring Relay Series



 



      SM175 3 Ph, 3W



   



SM175 3 Ph, 4W
Type Supply Monitoring Type Time Delay Asymmetry Voltage & Contact Arrangement   Cat. No. M.R.P. (`) Per Unit
                SM175 (3 Ph, 3W)       Phase loss + Phase Sequence Monitoring ON Delay 500 msec & OFF Delay 100 msec               208 – 480 VAC, 1 C/O (Steps of 208 – 220 – 380 – 400 – 415 – 440 – 480 VAC) MK21D5 1165
ON Delay 500 msec & OFF Delay 100 msec Phase Asymmetry (30% fixed)   MC21D5   1165
ON Delay 5 sec & OFF Delay 100 msec (0 to 15s Selectable) Phase Asymmetry (5% to 15% variable)   MA21DN   1520
Phase Loss + Phase Sequence + Under Voltage + Over Voltage monitoring (UV: -2% to   ON Delay 5 sec and Selectable OFF Delay (0 to 15 sec)       MD21DF     1520
-20% of 20% of , OV: 2% to )
Phase Loss + Phase Sequence + Under Voltage + Over Voltage (UV: -5% to -25% of , OV: 5% to 25% of ) Selectable ON Delay (0.5 to 15 sec) and OFF Delay 5 sec     Phase Asymmetry (10% fixed)   MG21DH   1700
ON Delay 5s and Selectable OFF Delay (0 to 15 sec)   MG21DF   1700
          SM175 (3 Ph, 4W) Phase loss+ Phase Sequence+ Under Voltage + Over Voltage (UV:-2% to -22% of , OV: 2% to 22% of )     Selectable ON delay (0 to 15 Sec), Selectable OFF delay (0 to 15 sec)       Phase Asymmetry (10% fixed)   120 to 277 VAC (3P, 4W), 1 C/O   MAG03D0424   1850
Phase loss+ Phase Sequence+ Under Voltage + Over Voltage (UV:-5% to -25% of      / 60% of (Fixed), OV: 5% to 25% of    / 110% of     (Fixed ))       240 VAC (3P, 4W), 1 C/O     MAG03D0425     1850
Phase loss+ Phase sequence+ Under Voltage + Over Voltage (UV:-5% to -25% / 80% of    (Fixed), OV: 110% of    (Fixed)) Selectable ON delay (0 to 15 sec/min), Selectable OFF delay (0 to 15 sec/min) Phase Asymmetry (10% fixed/ 5% to 25% Selectable)   MAG03D0426   1850
SM175 (3 Ph, 3W)   Phase loss Monitoring ON delay 750 msec & OFF delay 500 msec Phase Asymmetry (30% fixed)   415 VAC, 1 C/O MAG03D0427 1240
 

Current Monitoring relay (CMR)

  • l Microprocessor based relay protects against Overload, Phase reverse, Phase loss, Phase unbalance faults
  • Auto/ Manual reset selection
  • l Fail- safe protection with inbuilt CT upto 45A
  • Inverse time model with underload, locked rotor protection and selectable trip class (10A, 10, 20, 30)
  • l Definite time model with underload and selectable start and trip time

Current Monitoring relay

 

 

 

 

 

 

 

 

 

 

PhaseTypeCurrent & Contact ArrangementCat. No.

M.R.P. (`)

Per Unit

 

 

 

 

3 Phase

 

Inverse Time Current Monitoring Relay

2 – 5A 1 C/O17A422CB0

 

 

 

 

2080

3 – 9A, 1 C/O17A122CB0
8 – 24A, 1 C/O17A222CB0
15 – 45A, 1 C/O17A322CB0

 

Definite Time Current Monitoring Relay

2 – 5A 1 C/O17B422AA0
3 – 9A, 1 C/O17B122AA0
8 – 24A, 1 C/O17B222AA0
15 – 45A, 1 C/O17B322AA0
Definite Type / Instant Trip2 – 5A 1 C/O17B422PA0

 

 

 

 

1 Phase

 

Inverse Time Current Monitoring Relay

2 – 5A 1 C/O17C412EB0

 

 

 

 

2035

3 – 9A, 1 C/O17C112EB0
8 – 24A, 1 C/O17C212EB0
15 – 45A, 1 C/O17C312EB0

 

Definite Time Current Monitoring Relay

2 – 5A 1 C/O17D412DA0
3 – 9A, 1 C/O17D112DA0
8 – 24A, 1 C/O17D212DA0
15 – 45A, 1 C/O17D312DA0

 

Frequency Monitoring Relay Series Relay Type Time Delay Voltage & Contact Arrangement Cat. No. M.R.P. (`) Per Unit
  Over Frequency Monitoring Relay   ON Delay and OFF Delay of 500 ms (Fixed) 110 – 240 VAC, 1 C/O MI81BJ 2380
220 – 440 VAC, 1 C/O MI91BJ 2380
  Under/Over Frequency Monitoring Relay   ON Delay (Fixed) and OFF Delay Selectable 110 – 240 VAC, 1 C/O MI81BL 2600
220 – 440 VAC, 1 C/O MI91BL 2600
PTC Thermistor Relay Series
Relay Type Description Cat. No. M.R.P. (`) Per Unit
      Thermistor Relay 110 – 240 VAC, 2 C/O MJ83BK 2020
220 – 440 VAC, 2 C/O MJ93BK 2040
24 VAC/DC, 2 C/O MJA3BK 2360
110 – 240 VAC, 1 C/O MJ81BK 1865
220 – 440 VAC, 1 C/O MJ91BK 1895

Electro Mechanical Timers

EM 1000
Product Description Cat. No M.R.P. (`) Per Unit
EM 1000 ON Delay Auto Reset Synchronous Timer Single Range B••••• Table-1
EM 1000 Timing Ranges(SR) B 0.15 – 3.0 sec C 1.5 – 30 sec D 0.15 – 3.0 min E 1.5 – 30 min F 0.15 – 3.0 hrs G 1.5 – 30 hrs H 0.3 – 6.0 sec J 3.0 – 60 sec K 0.3 – 6.0 min L 3.0 – 60 min M 0.3 – 6.0 hrs N 3.0 – 60 hrs P 0.6 – 12 sec Q 6.0 – 120 sec R 0.6 – 12 min S 6.0 – 120 min T 0.6 – 12 hrs V 6 – 120 hrs
B Timing Ranges (MR) X 0.15 sec – 3.0 hrs Y 0.3 sec – 6.0 hrs Z 0.6 sec – 12.0 hrs
Voltage 3 110 VAC 50 Hz 4 240 VAC 50 Hz C 110 VAC 60 Hz D 240 VAC 60
Delay 1 Standard ON delay 2 With ‘NO VOLT’
Mounting B Base Mounting F Flush (door) Mtg. *270
Contact 1 1 Inst + 1 Del C/O 2 1 Inst + 2 Del C/O *260

Add to basic Price.

Contact : 240 VAC 6A (Resistive)

Table – 1
Single Range (SR) (In sec/min/hrs) M.R.P. (`) Per Unit for Single Range (SR) (In sec/min/hrs) Multi Range (MR) with 5 Ranges M.R.P. (`) Per Unit
0.15 – 3     4320 0.15 sec – 3 hrs   5125
0.3 – 6 0.3 sec – 6 hrs
0.6 – 12 0.6 sec – 12 hrs
1.5 – 30  
3.0 – 60
6.0 – 120
 

Hour Meter & Counter

Hour MetersProduct DescriptionCat. No.

M.R.P. (`)

Per Unit

 

HM36, 85 – 265 VAC Flush MountingLA25F1760
HM 36, 10 – 80 VDC Flush MountingLD17F11155
HM36, 92 – 264 / 270 – 460 VAC Base – DIN Mounting30A6B1835
HM36, 10 – 80 VDC Base/DIN Mounting30D1B11155
Digital Hour Meter/Digital Counter (Resettable)Z¨¨FB¨1385

 

Hour Meter / Counter

 

Z

 

FB

   
  

     Voltage  

H 10 – 80 VDC

7 85 – 265 VAC

J 12 – 48 VAC/DC

 

1 Hour Meter 2 Counter

     Bezel      A          Round B 24 x 48         

C Screw Mount

  

Earth Leakage Relay

Earth Leakage Relays







96 x 96 mm Earth Leakage Relay







DIN Mounted Earth Leakage Relay







CBCT







Rectangular CBCT
Current Range Type Voltage & Contact Arrangement Cat. No. M.R.P. (`) Per Unit
                              30mA – 30A       Panel mounted (96 x 96 mm) Earth Leakage Relay 110 – 240 VAC/DC, 1 C/O (Pre-alarm) + 1 C/O (Fault) 17K716QF4N 3745
110 – 240 VAC/DC, 1 C/O (Pre-alarm) + 1 C/O (Fault) with RS 485 17K716QF4M 5380
240 – 415 VAC/DC, 1 C/O (Pre-alarm) + 1 C/O (Fault) 17K726QF4N 3745
240 – 415 VAC/DC, 1 C/O (Pre-alarm) + 1 C/O (Fault) with RS 485 17K726QF4M 5380
    DIN mounted Earth Leakage Relay 110 – 240 VAC, 110 VDC, Manual reset 17G715GF2       3420
220 – 415 VAC, 220 VDC, Manual reset 17G745GF2
15 VDC, Manual reset 17G755GF2
110 – 240 VAC, 110 VDC, Auto reset 17G715KF2
220 – 415 VAC, 220 VDC, Auto reset 17G745KF2
15 VDC, Auto reset 17G755KF2
    CBCT (moulded case) for Type A & AC Current 38 mm ID 17H7NNHN3 1175
57 mm ID 17H7NNIN3 1590
70 mm ID 17H7NNQN3 1805
92 mm ID 17H7NNJN3 1975
120 mm ID 17H7NNLN3 2060
210 mm ID 17H7NNKN3 3885
    CBCT (moulded case) for Type AC Current 38 mm ID 17H7NNRN3 880
57 mm ID 17H7NNVN3 985
70 mm ID 17H7NNSN3 1045
92 mm ID 17H7NNTN3 1395
120 mm ID 17H7NNUN3 1620
Rectangular CBCT (moulded case) for Type AC Current 300 x 50 mm ID 17H9NNWN0 7755
350 x 150 mm ID 17H9NNXN0 9435

CBCT for Type AC : For applications with sinusoidal alternating current from 30mA to 30 A.

CBCT for Type A and AC : For applications with sinusoidal alternating current (from 30mA to 30A) & pulsating DC current (from 30mA to 3A). Please contact nearest branch office for requirements of higher dimension CBCTs.